Fraser Bar

The Fraser Bar meets the latest European emergency exit requirements of BS EN 179: 2008.
The emergency exit is activated by pushing the green push-pad in the direction of the arrow. This releases the single bolt.

After activation the bolt is held in the retracted position and a red activation panel is displayed. A key is required to re-set the Fraser Bar so the device complies with the requirements for high security (HS) devices with surreptitious anti-tamper protection.
Stirling Panic & Emergency Exit
features
  • 70 mm by 10 mm steel bolt with 50 mm throw
  • Independently type tested to BS EN 179: 2008
  • Bolt secured in retracted position after activation, requiring key for re-setting
  • Electric monitoring of bolt status
  • Steel core fixing
  • Supplied with a keep for an outward opening door hung in a timber frame
  • Finish - grey-white RAL 9002 leatherette powder coating co-ordinated with bright zinc plate
ADDITIONAL FEATURES (OPTIONAL)
  • Keeps available for double doors, inward opening doors and steel frames

Fraser Bar International Combined Ratings and Accreditations

Image
EN179
Above performance results are based on independent third party testing or assessment on selected doorsets.