Slimline Out-Of-Hours Controlled

The Slimline Out-of-hours Controlled has two methods of entry to suit both day time and out-of-hours security requirements. Automatic locking when the door is closed and is LPCB approved to LPS 1175 SR6 (on selected doorsets), offering high security protection against physical threats.
Slimline Out-Of-Hours Controlled
operations
Out-Of-Hours Lockdown - Activating the access control, the device will automatically unlock allowing the user to manually retract all of the shoot bolts using the lever handle. Upon door closure the bolts will automatically engage and fully secure If used with the appropriate restraint keep.

Day Time Entry - Activating the access control, the device will automatically unlock allowing the user to manually retract all of the shoot bolts using the lever handle. Upon door closure the bolts will automatically engage and fully secure If used with the appropriate restraint keep.

Out-of-hours Entry - A mechanical key is used to lock down entry via a secondary lock, preventing entry via access control. The same key is used to re-enable access control operation by unlocking the deadlock.

Exit - Access control exit, thumbturn exit or single handed means of escape is provided by either lever handle, push pad or full width panic bar. Exit function operated even during lock-down mode.
features
  • Full 316 grade stainless steel construction as standard
  • Surface mounted or mortice fitted solutions
  • Proven rack & pinion method 
  • 15mm (0.59") x 25mm (0.98") throw stainless steel bolts
  • Choice of exit device operators
  • Tested to over 1,000,000 cycles
  • Suitable for doors 2.2m (86.61”) high and extensions available for taller doorsets
  • Alternative direction & additional auxiliary bolts can be added
  • Optional bolt enhancement packs available for blast applications
  • Optional remote monitoring of bottom deadlock lock status
  • 12V DC solenoid lock release for access with Fail Secure, as standard
  • 24V DC optional
  • Fail Safe locking optional
  • Cranked lever handle as standard
benefits
  • Key operated deadlock for out of hours lockdown. The access control module is constrained during this time to prevent unauthorised entry attempts 
  • Tested on specific doorsets up to LPS 1175:SR6
  • Life safety device BSEN 179/1125 and UL305 compliant
  • Door securely locked when in closed position

Optional Entry Methods

Slimline Out-Of-Hours Controlled
Access Control
With Lever
Slimline Out-Of-Hours Controlled
Manual Key
Override
Slimline Out-Of-Hours Controlled
Out-Of-Hours
Key Deadlocking

Optional Exit Methods

Slimline Out-Of-Hours Controlled
Panic Bar
(meets EN1125)
Slimline Out-Of-Hours Controlled
Push Pad
(meets EN179)
Slimline Out-Of-Hours Controlled
Cranked lever
(meets EN179)
Slimline Out-Of-Hours Controlled
Silver Lever
(meets EN179)

Slimline International Combined Ratings and Accreditations

Below performance results are based on independent third party testing or assessment on selected doorsets.

Tested on specific doorsets up to:
LPS 1175

LPS 1175 SR6

LPS 1175 ISSUE8 B3

Slimline Out-Of-Hours Controlled
Blast - For details contact
our Technical Dept
Slimline Out-Of-Hours Controlled
EN1125/EN179/UL305

Slimline Out-Of-Hours Controlled 
UL10C (upto 3 hours)
BS476 PT22/EN1631-1
Slimline Out-Of-Hours Controlled
UL752/EN1522/23
FB1- FB7 & FSG
Slimline Out-Of-Hours Controlled
Seismic
Tested
Slimline Out-Of-Hours Controlled
Independently
Tested